EasyPro™ Stratus Rocking Piston Compressors with Sound Shield™

EasyPro™ SKU: SRC25SS

$755.99

Shipping calculated at checkout

EasyPro™ Stratus SRC Series rocking piston compressors with Sound Shield™ technology are designed for dependable, continuous-duty pond and lake aeration. Available in several horsepower options, these oil-less compressors deliver the airflow needed to operate bottom-diffused aeration systems at different water depths.

Sound Shield technology helps reduce operating noise while retaining the airflow performance needed for pond aeration. Choose from 1/4 HP, 1/2 HP, 3/4 HP, and 2 HP models, with 115V and 230V options available on select sizes.

Why Choose an EasyPro Stratus Compressor with Sound Shield?

When an aeration compressor runs day and night, dependable operation and noise level both matter. The Stratus SRC series combines a rocking piston design with Sound Shield technology to provide reliable airflow with reduced perceived noise.

  • Sound Shield technology: Designed to reduce perceived loudness by more than 50% compared with competing compressors, according to EasyPro.
  • Oil-less operation: No oil changes are required.
  • Continuous-duty design: Built for the demands of 24-hour pond aeration operation.
  • Smart-Start technology: Helps the compressor start under load.
  • Permanently lubricated bearings: Designed for dependable operation.
  • Durable construction: Die-cast body components and flexible cup materials.
  • Made for aeration: Available in several airflow capacities to suit different pond systems.

What Is Sound Shield Technology?

Sound Shield is a noise-reduction system developed for EasyPro Stratus rocking piston compressors. It helps quiet compressor operation without requiring you to sacrifice the airflow needed for aeration.

EasyPro reports a reduction of more than 50% in perceived loudness compared with competing compressors. The Sound Shield design is also intended to maintain approximately 95% of the compressor's airflow performance.

These compressors are a good option when the aeration equipment is installed near a home, patio, shoreline seating area, or another location where equipment noise is a concern.

EasyPro Stratus Compressor Specifications

Compare the horsepower, electrical requirements, maximum airflow, and pressure ratings below. Remember that maximum airflow is not the same as airflow delivered at your pond's operating depth.

Compressor Size Voltage Amps* Maximum Airflow Maximum Pressure
1/4 HP 115V or 230V 1.7 / 0.9 2.3 CFM 30 PSI
1/2 HP 115V or 230V 3.6 / 1.8 4.5 CFM 30 PSI
3/4 HP 115V or 230V 4.5 / 2.3 6.5 CFM 145 PSI
2 HP 230V only 10.0 12.0 CFM 125 PSI

*Amperage is measured at 10 feet of operating depth. For the 115V / 230V options, the first amperage figure is for 115V and the second is for 230V. Confirm the voltage of the selected compressor before connecting power.

Airflow at Different Pond Depths

This is one of the most important charts when selecting a pond aeration compressor. Water depth creates back pressure, which reduces the amount of air a compressor can deliver. A compressor rated at 4.5 CFM at the surface will deliver less air when operating diffusers at depth.

Use the chart to compare the approximate airflow available at common operating depths.

Compressor 10 ft 20 ft 30 ft 40 ft 50 ft
1/4 HP 2.2 2.0 1.9 1.8 1.7
1/2 HP 4.3 4.2 4.0 3.8 3.6
3/4 HP 6.0 5.5 5.2 5.0 4.7
2 HP 11.7 11.4 11.2 10.8 10.5

Airflow is shown in cubic feet per minute (CFM), based on EasyPro published specifications. Actual system airflow can vary with tubing length, fittings, diffuser back pressure, and installation conditions.

How Do I Choose the Right Horsepower?

The right compressor depends on more than pond acreage. You also need to consider the number of diffusers, their operating depth, and the airflow each diffuser requires.

  • 1/4 HP: A smaller-capacity option for systems with modest airflow requirements. Often considered for smaller ponds or a limited number of diffusers.
  • 1/2 HP: A step up in airflow for larger or more demanding aeration layouts.
  • 3/4 HP: Provides additional airflow capacity for systems requiring more air or higher operating pressure.
  • 2 HP: A high-capacity compressor for larger systems with substantial airflow requirements. This model requires 230V power.

Important: Do not select a compressor based on horsepower or maximum CFM alone. First determine the airflow required by your diffusers at the actual water depth. Then select a compressor that can supply that airflow at the required pressure.

Electrical Requirements and Operating Costs

These compressors are designed for continuous operation. Electrical cost will depend on the compressor size, operating conditions, and your local electricity rate.

Compressor Estimated Cost per 24 Hours Estimated Cost per 30 Days
1/4 HP $0.40 $12.00
1/2 HP $0.86 $25.80
3/4 HP $1.10 $33.00
2 HP $4.96 $148.80

Estimated costs are based on EasyPro's published figures at $0.09 per kWh and 24-hour operation. Your actual cost will vary with electricity rates and operating conditions.

What Electrical Service Do These Compressors Require?

The 1/4 HP, 1/2 HP, and 3/4 HP compressor sizes are available in 115V and 230V versions. The 2 HP model is available in 230V only.

Choose the voltage that matches the electrical service available at your installation location. A 230V compressor is not interchangeable with a 115V power supply. Have electrical connections installed in accordance with local codes and the compressor manufacturer's instructions.

Installation Considerations

Rocking piston compressors should be installed in a clean, dry, well-ventilated location protected from rain, flooding, and excessive moisture. Sound Shield helps reduce compressor noise, but the compressor still needs adequate ventilation and access for maintenance.

  • Install the compressor on a stable, level surface.
  • Protect the unit from direct exposure to weather and standing water.
  • Keep the air inlet filter clean and unobstructed.
  • Use properly sized air tubing and fittings for the system.
  • Confirm that the compressor's pressure and airflow capacity match the diffuser layout and water depth.

For outdoor installations, use an appropriate protective enclosure with adequate ventilation. Do not place the compressor in a sealed box or cabinet that can trap heat.

Maintenance and Replacement Parts

EasyPro Stratus SRC compressors use an oil-less design, so routine oil changes are not required. Periodic inspection and basic maintenance help keep the compressor operating properly.

  • Inspect and clean or replace the air inlet filter as needed.
  • Check air tubing and connections for leaks or damage.
  • Keep the compressor and ventilation openings free of debris.
  • Watch for changes in airflow, unusual noise, or excessive heat.
  • Use the appropriate manufacturer replacement parts when service is needed.

Replacement filters, repair kits, and other service components may be available depending on the compressor model.

Frequently Asked Questions

Can an EasyPro Stratus compressor run continuously?

Yes. The Stratus SRC series is designed for the demands of continuous-duty pond aeration. Follow the manufacturer's installation and maintenance instructions.

Do these compressors require oil?

No. The Stratus SRC rocking piston compressors use an oil-less design. Routine oil changes are not required.

Does Sound Shield reduce airflow?

EasyPro states that Sound Shield technology is designed to reduce perceived compressor noise while maintaining approximately 95% of airflow performance.

Which compressor size should I choose?

Choose based on the total airflow required by your diffusers at their operating depth. The airflow chart above helps compare compressor output as water depth increases. The number and type of diffusers also matter.

Can I use a 115V compressor where I have 230V power?

No. Select the compressor voltage that matches the electrical supply. The 115V and 230V versions are separate models.

Is the 2 HP compressor available in 115V?

No. The 2 HP Stratus model is listed as a 230V compressor.

What is the difference between maximum airflow and airflow at depth?

Maximum airflow is measured with little or no operating back pressure. As air is pushed deeper into the water, pressure increases and airflow decreases. For pond aeration, airflow at the diffuser's actual operating depth is the more useful number.

What warranty is included?

EasyPro lists a two-year limited warranty for Stratus SRC series compressors. Wearable parts are excluded. Refer to the manufacturer's current warranty terms for complete coverage details.

Choose the Right Compressor for Your Aeration System

Whether you're replacing an existing compressor or designing a new pond aeration system, start with the airflow your diffusers need at operating depth. Compare the Stratus models above, check your available voltage, and choose the capacity that fits your system.

Need help matching a compressor to your diffuser setup? Review the airflow requirements and operating depth before choosing. A properly matched compressor helps your aeration system deliver the airflow it was designed to provide.