EasyPro™ TH Series Stainless Steel Pumps 115V & 230V Options

EasyPro™ SKU: TH150

$564.29

Shipping calculated at checkout

The EasyPro TH Series stainless steel pumps are designed for ponds, waterfalls, streams, fountains, and other continuous-duty water circulation applications. Four pump sizes are available, from 3,100 to 6,000 GPH, with 115V and 230V options available for the TH Series. Compare the flow rates, pumping heights, electrical requirements, and available cord options below to choose the right TH Series pump for your application.

Model Max Flow HP Voltage Amps Max Head Outlet Cord
TH150 3,100 GPH 1/4 HP 115V 2.6–3.1 23 ft 2" FPT 20 ft
TH1502 3,100 GPH 1/4 HP 230V 1.3–1.5 23 ft 2" FPT 20 ft
TH250 4,100 GPH 1/3 HP 115V 3.0–4.2 30 ft 2" FPT 20 ft
TH2502 4,100 GPH 1/3 HP 230V 1.5–2.1 30 ft 2" FPT 20 ft
TH400 5,100 GPH 1/2 HP 115V 3.7–6.0 36 ft 2" FPT 20 ft
TH4002 5,100 GPH 1/2 HP 230V 1.8–3.0 36 ft 2" FPT 20 ft
TH750 6,000 GPH 1 HP 115V 6.0–9.9 46 ft 2" FPT 20 ft
TH7502 6,000 GPH 1 HP 230V 3.0–4.9 46 ft 2" FPT 20 ft

Note: Maximum flow is measured at low or zero head. Actual flow decreases as pumping height and plumbing resistance increase. EasyPro also offers optional 50' and 100' power cords for the TH Series.

 

How Much Water Will an EasyPro TH Series Pump Deliver at Different Heights?

The maximum GPH rating of an EasyPro TH Series pump is measured at low or zero head, so the actual flow rate will decrease as pumping height increases. EasyPro provides performance data at several heights to help you estimate the flow you can expect from each model. For example, the TH150 is rated at 3,100 GPH at zero head, but its published flow is approximately 2,100 GPH at 10 feet of head. The TH250 delivers approximately 3,240 GPH at 10 feet, while the TH400 delivers approximately 4,380 GPH at 10 feet.

When selecting a pump, don't size it based solely on the maximum GPH rating. Consider the total pumping height and plumbing resistance to determine how much water the pump will actually deliver at your installation.

Which EasyPro TH Series Pump Do I Need?

Choosing the right TH Series pump starts with determining how much water you need and how high you need to pump it. For waterfalls and streams, consider the desired width and depth of the waterfall along with the vertical lift from the pond surface to the point where the water is discharged.

You should also account for friction loss from the pipe, fittings, valves, and other plumbing components. A pump that appears to provide enough flow based on its maximum GPH rating may deliver considerably less once it is operating against head pressure and plumbing resistance.

The TH Series includes four pump sizes, from the 3,100 GPH TH150 to the 6,000 GPH TH750. In general, choose the model that provides the required flow at your actual operating head rather than simply choosing the pump with the highest advertised GPH.

What's the Difference Between the EasyPro TH150, TH250, TH400, and TH750?

The primary difference between the TH Series models is their flow capacity and maximum pumping height. As the model size increases, both the available flow and maximum head increase.

  • TH150: 3,100 GPH maximum flow and 23-foot maximum head

  • TH250: 4,100 GPH maximum flow and 30-foot maximum head

  • TH400: 5,100 GPH maximum flow and 36-foot maximum head

  • TH750: 6,000 GPH maximum flow and 46-foot maximum head

Each model is available in a 115V version and a corresponding 230V version. All EasyPro TH Series pumps feature a durable 304 stainless steel motor housing designed for dependable operation in pond and water feature applications.  Use the comparison chart above to compare the models, electrical requirements, power consumption, and other specifications.

Remember that maximum head is the point at which the pump produces essentially no useful flow. It should not be treated as the recommended operating height. Use the pump's performance curve to determine the expected flow at your required head.

What Is the Difference Between the 115V and 230V EasyPro TH Series Pumps?

The EasyPro TH Series is available in both 115V and 230V configurations. The corresponding 115V and 230V models have the same maximum flow and maximum head ratings, while their electrical requirements differ.

For example, the TH150 and TH1502 are both rated at 3,100 GPH with a maximum head of 23 feet. The TH150 operates at 115V with a published maximum amp range of 2.6–3.1 amps, while the TH1502 operates at 230V with a published maximum amp range of 1.3–1.5 amps.

Choose the voltage that matches the electrical supply available for your installation. Always verify the required voltage and amperage before installing the pump.

Are EasyPro TH Series Pumps Designed for Continuous Operation?

Yes. The EasyPro TH Series is designed for continuous-duty water circulation and is intended for applications such as ponds, waterfalls, streams, fountains, and other water features. EasyPro describes the TH Series as having a rugged motor designed for long life and continuous-duty operation. The pumps also include built-in thermal overload protection.

For continuous operation, the pump must remain properly submerged. EasyPro's instructions specify that the pump should be fully submerged for continuous operation and should not be operated out of water.

Proper installation and adequate water flow around the pump are important for reliable operation. Plumbing size and system resistance also affect pump performance, so the pump should be selected for the actual conditions of the installation.

EasyPro TH Series Pump Dimensions and Performance Curves

The EasyPro TH Series pump performance curves show how much water each pump delivers at different pumping heights. As the pumping height increases, the flow rate decreases. Find your required pumping height on the chart and follow across to the corresponding pump curve to estimate the actual flow rate in GPH.

Remember that the advertised maximum GPH is measured at little or no pumping height. For the best pump selection, compare the flow rate at your actual operating height, allowing for additional resistance from pipe length, fittings, and other plumbing components.

 

TH Pump Specs

Related Products

50' and 100' cord options can be seen here.